 the PZEM-016 AC communication module,

the module is mainly used for measuring AC voltage, current, active power, frequency, power factor and active energy, the module is without display function, the data is read through the RS485 MODBUS interface.


1.Function description

(a) Voltage Measuring range:80~260V 

  Resolution: 0.1V

  Measurement accuracy: 0.5%

(b) Current

 Measuring range: 0~100A(PZEM-016)

 Starting measure current: 0.02A(PZEM-016)

 Resolution: 0.001A

 Measurement accuracy: 0.5%

(c) Active power 

 Measuring range: 0~23kW(PZEM-016)

 Starting measure power: 0.4W

 Resolution: 0.1W

 Display format:

<1000W, it display one decimal, such as: 999.9W

≥1000W, it display only integer, such as: 1000W

 Measurement accuracy: 0.5%


(d) Power factor

 Measuring range: 0.00~1.00

 Resolution: 0.01

 Measurement accuracy: 1%

(e) Frequency

 Measuring range: 45Hz~65Hz

 Resolution: 0.1Hz

 Measurement accuracy: 0.5%

(f) Active energy

 Measuring range: 0~9999.99kWh

 Resolution: 1Wh

 Measurement accuracy: 0.5%

 Display format:

<10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh

≥10kWh, the display unit is kWh, such as: 9999.99kWh

(g) Reset energy: use software to reset.



datasheet:   https://images-na.ssl-images-amazon.com/images/I/81GtkIOyZaL.pdf

Average Rating(<% products.rating %>)

User Rating   

<% products.rating %> average based on <% products.rate_user %> reviews.


Write A Review
5 stars
<% products.rate5 %>
4 stars
<% products.rate4 %>
3 stars
<% products.rate3 %>
2 stars
<% products.rate2 %>
1 star
<% products.rate1 %>